CASE REPORT |
https://doi.org/10.5005/jihr-11055-0018 |
From Scan to Solution: Patient-centered Maxillofacial Rehabilitation Using a 3D-printed Resin Model to Fabricate an Obturator: A Case Report
1,2,6Department of Prosthodontics, Shri Yashwantrao Chavan Memorial Medical and Rural Development Foundation's Dental College and Hospital, Ahilyanagar, Maharashtra, India
3Department of Prosthodontics, Saraswati Dhanwantari Dental College and Hospital, Parbhani, Maharashtra, India
4Department of Pediatric and Preventive Dentistry, People's College of Dental Sciences and Research Centre, Bhopal, Madhya Pradesh, India
5Department of Pediatric and Preventive Dentistry, Shri Yashwantrao Chavan Memorial Medical and Rural Development Foundation's Dental College and Hospital, Ahilyanagar, Maharashtra, India
Corresponding Author: Yukta Trambakrao Gadhe, Department of Prosthodontics, Shri Yashwantrao Chavan Memorial Medical and Rural Development Foundation's Dental College and Hospital, Ahilyanagar, Maharashtra, India, Phone: +91 9518756006, e-mail: [email protected]
Received: 11 January 2026; Accepted: 06 February 2026; Published on: 30 April 2026
ABSTRACT
Background: Rehabilitation of edentulous postmucormycosis maxillary defects is challenging due to extensive anatomical loss, restricted intraoral access, and financial limitations. Surgical reconstruction or implant-supported prostheses may be contraindicated, while conventional acrylic obturators often fail to achieve retention and stability.
Case description: A 67-year-old male with controlled diabetes, previously treated with amphotericin B following COVID-19-associated mucormycosis, presented 3 years postmaxillectomy with complete edentulism and a vertical Class II defect (>50% vertical bone loss). Symptoms included impaired mastication, swallowing difficulty, and social isolation. Prior conventional obturator attempts were unsuccessful.
Intervention: Computed tomography (CT) scans (1 mm slices, Siemens Somatom) were processed using RadiAnt, Meshmixer, and Chitubox to generate STL data, which was 3D-printed (Elegoo Mars 3). A wax bulb prototype was sculpted on a 3D-printed model utilizing undercuts for retention and processed with Mollosil silicone (10:1 mix, 10 minutes at 45 °C). A vinyl polysiloxane (VPS) pickup impression enabled fabrication of a definitive heat-polymerized polymethyl methacrylate (PMMA) obturator. Mollosil bulb bonded to acrylic via Mollosil adhesive and mechanical retention.
Outcome: The hybrid obturator restored retention, stability, occlusion, speech, and deglutition. Follow-ups at 48 hours, 1 week, 1 month, and 6 months confirmed sustained function, oral–nasal separation, and patient satisfaction without complications.
Conclusion: This CT-based hybrid digital–conventional workflow with a flexible Mollosil bulb offers a cost-effective, minimally invasive solution when conventional methods fail.
Keywords: Case report, CT-based digital planning, Edentulous maxillary defect, Maxillary obturator, Maxillofacial prosthesis, Mollosil obturator, Patient-centered rehabilitation, Three-dimensional-printed resin model
How to cite this article: Gadhe YT, Bhatia AP, Dod A, et al. From Scan to Solution: Patient-centered Maxillofacial Rehabilitation Using a 3D-printed Resin Model to Fabricate an Obturator: A Case Report. J Integr Health Res 2025;2(2):78–82.
Source of support: Nil
Conflict of interest: None
Patient consent statement: The author(s) have obtained written informed consent from the patient for publication of the case report details and related images.
INTRODUCTION
The term obturator originates from the Latin word obturare, meaning “to close” or “shut off.” As defined by Boucher, an obturator is a prosthesis designed to close palatal openings resulting from congenital or acquired defects.1 According to the Glossary of Prosthodontic Terms-2023 (GPT-10), maxillofacial prostheses restore separation between the oral and nasal cavities, thereby improving speech, deglutition, and mastication.2
Maxillary defects most commonly result from surgical resection for malignancy, trauma, or aggressive infections and pose significant prosthodontic challenges due to anatomical complexity and compromised support structures.3 During the second wave of the COVID-19 pandemic in India, there was a marked surge in rhino–orbital–cerebral mucormycosis cases, frequently necessitating partial or total maxillectomy to ensure patient survival.4,5 Many survivors subsequently present years after surgery with persistent functional impairment, nutritional compromise, and psychosocial distress.
In clinical practice, delayed presentation is often compounded by financial constraints and repeated failure of conventional prosthetic rehabilitation. Surgical reconstruction and implant-supported prostheses may be contraindicated or unaffordable, particularly in elderly or medically compromised patients. Conventional obturators incorporating rigid acrylic bulbs may fail to provide adequate retention and stability in edentulous patients with large defects and restricted intraoral access, resulting in compromised speech, mastication, and quality of life.6,7
Recent advances in digital dentistry, including computed tomography (CT)-based computer-aided design/computer-aided manufacturing (CAD/CAM) workflows and 3D printing, allow accurate replication of complex maxillary defects while minimizing reliance on conventional impression techniques.8 However, reports describing impression-free, hybrid digital–conventional workflows combined with flexible obturator materials in postmucormycosis edentulous patients remain limited.
The novelty of this case lies in the use of a CT-derived 3D-printed defect model to fabricate a definitive obturator incorporating a flexible Mollosil bulb following failure of a conventional acrylic bulb obturator in a financially constrained, edentulous postmucormycosis patient. This clinically driven approach was adopted to improve retention, stability, comfort, and function while avoiding invasive and costly treatment modalities.
CASE DESCRIPTION
A 67-year-old male patient presented 3 years after a surgical maxillectomy performed for rhino–orbital–cerebral mucormycosis during the COVID-19 pandemic. He had completed systemic antifungal therapy consisting of liposomal amphotericin B followed by oral posaconazole, with no evidence of disease recurrence. Medical history revealed controlled type 2 diabetes mellitus, with no other systemic contraindications at the time of prosthetic rehabilitation. The surgical site was completely healed, with no signs of active infection or inflammation. The patient reported impaired mastication, nasal regurgitation, and difficulty in speech.
Intraoral examination revealed complete maxillary edentulism with unilateral maxillary discontinuity. Preprosthetic evaluation included assessment of defect size, residual palatal support, depth of soft tissue undercuts, tissue resiliency, interarch space, mandibular prosthesis status, and mouth opening. The defect was classified as Class II according to the Vertical Liverpool classification, indicating a unilateral vertical defect with preservation of the contralateral maxilla, which significantly influenced obturator design and retention strategy (Fig. 1). A customized obturator with a flexible bulb was planned.

Fig. 1: Preoperative condition of the defect
Due to restricted intraoral access, conventional impression techniques were contraindicated. Multislice CT data (slice thickness 0.6–1.0 mm) were processed using RadiAnt Digital Imaging and Communications in Medicine (DICOM) viewer and exported as STL files. Mesh refinement was performed in Meshmixer, the model was sliced in Chitubox, and the parts were fabricated on an SLA 3D printer at a layer thickness of 50 µm to obtain an accurate anatomical replica of the defect (Fig. 2).

Fig. 2: Designing a 3D-printed model in Exocad
A wax prototype of the obturator bulb was sculpted on the printed model (Fig. 3), invested (Fig. 4), and processed using Mollosil (DETAX GmbH, Germany) to fabricate a flexible silicone bulb (Fig. 5). After intraoral evaluation of extension, comfort, and sealing efficiency (Fig. 6), a vinyl polysiloxane pickup impression was made to record the relationship between the silicone bulb and the denture-bearing tissues (Fig. 7). The impression was poured to obtain a master cast (Fig. 8), followed by jaw relation recording and try-in procedures (Fig. 9).

Fig. 3: 3D-printed model and wax pattern

Fig. 4: Invested wax pattern of the bulb

Fig. 5: Mollosil bulb

Fig. 6: Intraoral application of the Mollosil bulb

Fig. 7: Pickup impression

Fig. 8: Master cast

Fig. 9: Try-in
A definitive obturator was fabricated using heat-polymerized polymethyl methacrylate (PMMA), with mechanical retention provided by a retentive undercut in the wax prototype and chemical bonding achieved using the manufacturer-recommended Mollosil adhesive. Retention was achieved through engagement of available soft tissue undercuts by the flexible bulb, while the rigid PMMA framework provided structural support. An occlusal scheme was established to enhance functional stability and minimize lateral stresses (Fig. 10). Final adjustments were completed before insertion (Fig. 11).

Fig. 10: Definitive obturator

Fig. 11: Postoperative intraoral photograph
Clinical outcomes were evaluated based on prosthesis retention and stability, speech intelligibility during conversational speech, and patient-reported masticatory function. The patient reported complete resolution of nasal regurgitation, improved speech clarity, and the ability to consume a soft-to-moderate consistency diet. Prosthesis retention and comfort were assessed as satisfactory by both the clinician and the patient.
At follow-up visits (48 hours, 1 week, 1 month, and 6 months), peri-defect tissues demonstrated healthy adaptation without signs of inflammation, ulceration, or fungal recurrence. Prosthesis retention and functional stability were maintained, with no evidence of material degradation or detachment of the Mollosil bulb. No adverse events, complications, or negative outcomes were observed.
CLINICAL TIMELINE
The patient underwent maxillectomy for mucormycosis in 2021, followed by completion of antifungal therapy and surgical healing between 2021 and 2022. From 2022 to 2024, multiple prosthodontic consultations were undertaken, including a failed conventional acrylic obturator due to inadequate retention. The patient presented to the current department in 2025, when a CT-based digital workflow was implemented for definitive obturator fabrication. Postinsertion evaluations were conducted from 48 hours up to 6 months.
DISCUSSION
Maxillofacial prostheses provide a lightweight, adaptable, and esthetically acceptable solution for rehabilitation when surgical reconstruction is contraindicated due to inadequate bone support, patient preference, cosmetic expectations, economic constraints, or the extent of the defect. These factors play a critical role in material selection and prosthesis design.
Rehabilitation of edentulous patients with maxillary defects remains particularly challenging. In the present case, complete maxillary edentulism, a large unilateral defect, restricted mouth opening, and the presence of a fixed mandibular prosthesis limited conventional treatment options. Surgical reconstruction and implant-supported prostheses were excluded due to the patient's socioeconomic constraints.
Previous reports have described obturator fabrication using either conventional impression techniques or fully digital workflows.8,9 However, limited literature addresses scenarios in which conventional obturators fail due to inadequate retention, particularly in edentulous postmucormycosis patients with restricted oral access. In this case, a prior rigid acrylic bulb obturator was unsuccessful, necessitating an alternative approach.
To overcome these limitations, a CT-derived 3D-printed model of the defect was fabricated, allowing accurate visualization and precise fabrication of a customized obturator bulb.9 Integration of 3D printing in maxillofacial prosthodontics enhances accuracy, reproducibility, and customization, particularly in anatomically complex defects.
Unlike rigid acrylic bulbs, the flexible Mollosil bulb used in this case permitted atraumatic insertion through a restricted oral opening and improved engagement of available soft tissue undercuts, consistent with findings reported by Venugopalan et al.3 Mollosil offers biocompatibility, resilience, patient comfort, and ease of maintenance,3,10 contributing to improved retention and stability without invasive procedures. This hybrid digital–conventional approach represents a pragmatic and cost-effective solution for economically constrained patients.
This case demonstrates a simplified, minimally invasive rehabilitation strategy using a flexible obturator bulb fabricated through a hybrid digital workflow. Limitations include the single-case design and lack of long-term comparative data. Further clinical studies with larger sample sizes and extended follow-up are required to validate the reproducibility and long-term effectiveness of this approach.
CONCLUSION
This case highlights the effective use of a hybrid digital–conventional workflow for rehabilitating a postmucormycosis maxillary defect. CT-based 3D printing enabled accurate defect replication, while a flexible Mollosil bulb combined with a PMMA obturator provided a customized, functional, and economical solution. The approach overcame impression challenges in edentulous patients with limited access and improved retention, comfort, speech, and mastication, underscoring the value of digital technologies in patient-centered maxillofacial prosthodontics.
Clinical Significance
This case demonstrates that a hybrid digital–conventional workflow using CT-based 3D printing and a Mollosil bulb obturator provides a practical, minimally invasive, and cost-effective solution for rehabilitating complex postmucormycosis maxillary defects, particularly in edentulous patients with limited intraoral access, resulting in improved retention, function, and patient comfort.
ETHICAL APPROVAL
The study was approved by the Institutional Ethics Committee, Yashwantrao Chavan Memorial Medical and Rural Development Foundation's Dental College and Hospital, Ahilyanagar, India (Approval date: 30 June 2025). The study was conducted in accordance with ICH-GCP and ICMR ethical guidelines.
ACKNOWLEDGMENTS
Not applicable. The authors did not receive any external funding, technical assistance, or third-party support requiring acknowledgment.
ORCID
Shilpi Tiwari https://orcid.org/0000-0002-4140-6918
Sudarshan Pramod Pargaonkar https://orcid.org/0009-0000-1214-451X
Kirti Ramrao Hange https://orcid.org/0009-0006-0661-3467
REFERENCES
1. Desjardins RP. Obturator prosthesis design for acquired maxillary defects. J Prosthet Dent 1978;39(4):424–435. DOI: 10.1016/s0022-3913(78)80161-9
2. Layton DM, Morgano SM, Muller F, et al. Glossary of prosthodontic terms 2023. J Prosthet Dent 2023;130(4 Suppl 1):e1–e126.
3. Venugopalan S, Salian K. Silicone obturator: as an aid for retention of the interim prosthesis in an edentulous maxillary defect. SRM J Res Dent Sci 2013;4(1):39–42.
4. Bhanushali P, Katge F, Deshpande S, et al. COVID-19: changing trends and its impact on the future of dentistry. Int J Dent 2020;2020:8817424. DOI: 10.1155/2020/8817424
5. Chander J. Textbook of Medical Mycology. Delhi: Jaypee Medical Publishers Pvt. Ltd; 2017. pp. 554–597.
6. Parab MM, Aras MA, Chitre V. Technique of fabrication of definitive hollow obturator for partial maxillectomy patient. Int J Prosthodont Restor Dent 2011;7(1):38–41.
7. Kattadiyil M, Mursic Z, AlRumaih H. Intraoral scanning of hard and soft tissues for partial removable dental prosthesis fabrication. J Prosthet Dent 2014;112(3):444–448. DOI: 10.1016/j.prosdent.2014.03.022
8. Torabi K, Farjood E, Hamedani S. Rapid prototyping technologies and their applications in prosthodontics: a review of literature. J Dent (Shiraz) 2015;16(1):1–9. PMID: 25759851.
9. Tasopoulos T, Kouveliotis G, Polyzois G, et al. Fabrication of a 3D printing definitive obturator prosthesis: a clinical report. Acta Stomatol Croat 2017;51(1):53–58. DOI: 10.15644/asc51/1/7
10. Hou YZ, Huang Z, Ye HQ, et al. Inflatable hollow obturator prostheses for patients undergoing an extensive maxillectomy: a case report. Int J Oral Sci 2012;4:114–118. DOI: 10.1038/ijos.2012.22
________________________
© The Author(s). 2025 Open Access. This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (https://creativecommons.org/licenses/by-nc/4.0/). This license permits non-commercial use, distribution, and reproduction in any medium, provided the original author and source are credited, a link to the license is included, and any changes are indicated.